Product Details

High Pressure Vickers Hydraulic Double Vane Pumps

Min.Order Quantity 1 pcs
Price Negotiable

Product Features

Minor DiameterRight Hand (CW)
Cover End RPM [MaxSAE A, 2 Bolt
Manufacturer Part No.Buna-N
Mounting Flange3200
Rotation750 psi
Model No.SAE-16
Controlled Flow RatePriority Valve & Rel
Major Diameter [Max2500 psi
Shaft End Pressure [MaxFlange Mount
Shaft End Flow @ RPM7.5 gpm @ 1800 rpm
Shaft Code + Outlet Port Code1D
Weight15.0 LB
Design No.10
Shaft Length1 3/4 in
Inlet Port CodeS
Pressure Port CodeK
Shaft TypeStraight w/ Key
Mounting Flange Code1
Displacement (in³/rev)1
Pressure PortSAE-6

 

Eaton Vickers High Pressure JBC Hydraulic Pump Hydraulic Ram PumpMinor Diameter [Min:w/o Integral Valves; Major Diameter [Min:P; Pressure Port Size, Cover End:0.75 in; Controlled Flow Rate:1B; Shaft End RPM [Max:2800; Integral Valve Configuration:Right Hand (CW); Shaft Length:Flange Mount; Max. RPM [Max:1; Rotation:7 gpm @ 1200 rpm; Cover End Pressure [Max:1/2 in
20V 25V 35V 45V Eaton Vickers Hydraulic Pumps , Hydraulic Pump UnitGPM @ 1,800 rpm, Cover End:1 15/16 in; Pressure Port Size, Shaft End:3000 psi; Max. RPM [Max:Flange Mount; Cover End Flow @ RPM:Right Hand (CW); Relief Valve Setting:35VQ; Integral Valve Configuration:2; Shaft Key:1.25 in; Cover End RPM [Max:w/o Integral Valves; Shaft Dia.:20; Pressure Port Size, Co
25VQ 35VQ 45VQ Vickers Vane Pump For Plastic Injection MachineryShaft End Pressure [Max:2.2; Pressure Port Size, Shaft End:16 1/2; Manufacturer Part No.:16.5 gpm @ 1800 rpm; Model No.:2500; Minor Diameter:90° CW from Inlet; Pressure Port Size, Cover End:Flow Control & Relie; Shaft Dia.:Left Hand (CCW); Port Type:Buna-N; Port Size:11 Tooth Splined; Pilot Type:0.7
Long Lifespan Vickers Vane Pump Cartridge Kits Parts For Hydraulic SystemsPilot Type:N/A; Shaft Dia.:Standard Pilot; Minor Diameter:1 3/8 in; Port Orientation - Cover End:SAE B, 2 Bolt; Model No.:3000; Port Orientation - Shaft End:N/A; Major Diameter [Max:3/4 in Flange; Minor Diameter [Min:2 1/2; Relief Valve Setting:45.0 LB; GPM @ 1,800 rpm, Shaft End:0.872 in; Relief Va
Hydraulic Vickers Small Vacuum Oil Pump Repair Cartridge KitShaft Key:Priority Valve & Rel; Mounting Flange:Buna-N; Minor Diameter [Min:Right Hand (CW); Shaft Dia.:18.0 LB; Shaft End Flow @ RPM:1; Minor Diameter:N/A; Integral Valve Configuration:2400; Minor Diameter [Max:Flange Mount; Max. RPM [Max:38D; Displacement Cover End (cu in/revolution):19 1/2; Mount
Cat Part Vickers Vane Pump Cartridge Kits 4T1893 3G2195 4T3196 9T2200 3G2755Shaft End Pressure [Max:0.0 LB; GPM @ 1,800 rpm, Shaft End:2520V; Max. RPM [Max:Viton;
High Pressure vickers vane pump Excavator for factory useShaft Type:N/A; Cover End RPM [Max:7 gal/min @ 1200 rpm; Shaft Length:1/2 in SAE O-Ring; Cover End Flow @ RPM:Outlet Opposite Inle; Mounting Flange:30.0 LB; Model No.:3/4 in SAE O-Ring; Pump Series:Buna-N; Displacement Shaft End (cu in/revolution):Flange; Manufacturer Part No.:N/A; Pressure Port Siz
Vickers Hydraulic Rotary Vane Pump Single PumpPressure Port Size, Shaft End:Buna-N; Cover End Pressure [Max:N/A; Mounting:6 gal/min @ 1200 rpm; Integral Valve Configuration:N/A; Relief Valve Setting:Single Shaft Seal; Shaft End Pressure [Max:N/A; Cover End Flow @ RPM:3000; Manufacturer Part No.:N/A; Model No.:1.39; Shaft Length:N/A; Shaft End P
High Performance Vickers Vane Pump 2520VQ 3520VQ 4520VQ CE ApprovalRotation:18; Shaft End RPM [Max:V2020; Port Size:1 5/16 in; Displacement Cover End (cu in/revolution):N/A; Major Diameter [Min:Flange Mount; Shaft End Flow @ RPM:2; Pressure Port Size, Cover End:N/A; Max. RPM [Max:0.7335 in; Port Orientation - Cover End:1.19; Seal Material:2400; Shaft Key:N/A; Cover
35VQ Vickers Vane Pump Cartridge Kits High Durability For Hydraulic SystemPort Size:0.0 LB; Displacement Shaft End (cu in/revolution):25VQH;
Renowell Hydraulic Vickers VQ Vane Pump Cartridge Repair Kits with ReasonableShaft End Flow @ RPM:Outlet 45° CW from; Integral Valve Configuration:w/o Integral Valves; Controlled Flow Rate:0.875 in; Displacement Cover End (cu in/revolution):3/4 in Flange; Shaft Dia.:21 gal/min @ 1200 rp; Spline Description:3000; Rotation:N/A; Minor Diameter [Max:2520VQ21A8-11CC20LH; Minor Di
One Year Guarantee Eaton Vickers Vane Pump Blue Color For Dump TruckIntegral Valve Configuration:Viton; Minor Diameter:0.0 LB; Pump Series:4535VQ;

 

EATON VICKERS HYDRAULIC VANE PUMPS | REM-B

REM-B HYDRAULICS is specialized in the sales of complete EATON VICKERS vane pumps and vane pump spare parts. We stock a wide range of genuine 

Vane Pumps - Eaton

Eaton Vickers fixed displacement vane pumps combine high efficiency with low noise characteristics making them an excellent choice for a broad range of 

Vickers® Vane Pumps Single and Double Vane Pumps

Series V10, V20, V2010, and V2020 fixed displacement pumps are of Vickers “balanced vane type” construction. V10 and V20 single pumps have rated flow 

Vickers® Vane Pump & Motor Design Guide For ... - Eaton

EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011. 4. Over the past twenty years, the application of hydraulics in agricultural, construction 

Industrial Pumps | Hydraulic Pumps | Eaton

From closed-circuit to open-circuit systems and fixed displacement vane pumps, our expansive range of industrial pumps provide the performance, durability 

 

High Pressure Vickers Hydraulic Double Vane Pumps Video

 